Products
-
Laboratory construction of the overall solution
-
Biosafety protection laboratory solutions
-
Laboratory ventilation series
-
Experiment table cabinet series
-
Flammable and poisonous cabinet series
-
CNC machining equipment
-
Laboratory accessories
-
Clean room engineering
-
Intelligent laboratory
-
Digital laboratory
-
Middle School Standardization Laboratory
-
Analytical Instruments
-
Constant temperature and humidity laboratory
-
Laboratory centralized gas supply system
-
Laboratory pure water system
-
Laboratory exhaust gas purification system
SY-8100 High Performance Liquid Chromatograph
Instrument introduction:
The scientific and reasonable function and structure design can meet the accuracy and reproducibility required by the precision analysis instrument experiment to the greatest extent.
The modular design of building blocks allows each module to be used separately and is easy to maintain.
Chinese interface, powerful instrument counter-control and chromatographic data processing workstation make instrument control and data processing easy.
Innovation
◆The high-pressure infusion pump adopts electronic pulsation suppression technology, which replaces the traditional mechanical buffer and completely solves the major failures caused by frequent leakage of the mechanical buffer. In addition, the adoption of this new technology also minimizes the dead volume of the infusion system.
◆The wavelength positioning method of the multi-wavelength ultraviolet spectrophotometer is directly realized by the single-chip microcomputer by controlling the rotation of the grating (that is, the sinusoidal relationship between the wavelength and the grating angle is realized by software), which replaces the traditional sinusoidal rod mechanism (monochromator) and overcomes the The wavelength positioning error caused by the mechanical wear of the rod drive and the backlash also overcomes the accident of the monochromator collision caused by the misoperation.
*Counter control and chromatography data processing workstation
The perfect anti-control function can control and detect the parameters of all components including the column oven.
Switching between Chinese and English operation interface, easy to operate.
One injection analysis is completed, and the chromatographic data can be automatically processed to obtain a perfect spectrum.
The background operation function can reprocess the spectrum saved in the workstation while sampling analysis.
Set the gradient program of the infusion pump and the wavelength time program of the detector.
Can freely design the report interface.
Timer shutdown function.
main feature:
Counter-control
RELATED PRODUCTS
SAUNDERS
WRITE A MESSAGE TO US
