Use of digital software (2)
Product

Use of digital software (2)

Number of views:
1000
1
Product description

  Four, working mode setting

  1. Options

  In this function, users can set various conditions and rules for sampling.

  (1) Basic parameters

  Sampling Rate. Set the sampling frequency of the sensor in the next sampling.

  Photoelectric gate working mode. Set the working mode of the photoelectric gate sensor in the next sampling.

1

  (2) Start experiment parameters

  Sampling method

  Continuous sampling. Click the start sampling button to start sampling until the conditions for ending the experiment are met.

  Snapshot sampling. Click Start Sampling to start reading data, but only when you click the "Snapshot Sampling" button will the data be recorded once.

  Threshold trigger. It is necessary to set which sensor is the reference sensor for the threshold, and to set the trigger condition whether it is greater than the threshold or less than the threshold, and the value of the threshold. Click Start Sampling to start reading data, but only when the threshold conditions are met will it start recording data.

  Value sampling. No input value is collected.

  Experimental acquisition data processing

 Same data processing: before each click to start the experiment, check this option. In the next experiment, the software will only collect changed sensor data. (For example: the data are listed as 1, 1, 1, 2. If this option is checked, the software will only choose to collect the numbers 1, 2)

1

  (3) End of experiment parameters

  End by time. The sampling time needs to be set, in seconds. When sampling starts, if the total sampling time reaches the specified number of seconds, sampling will automatically stop.

  End by the number of data rows. Need to set the total number of rows sampled. When the number of sampled data rows reaches this value, the sampling will be notified automatically.

  End by data threshold. It is necessary to set which sensor is the reference sensor for the threshold, and to set the trigger condition whether it is greater than the threshold or less than the threshold, and the value of the threshold. After sampling starts, when the collected data meets this condition, sampling will automatically stop.

1

  2. Sensor definition

  Set different parameters related to the sensor. The factory has set these parameters before leaving the factory, and it is recommended that users do not change any of them casually. If you really need to change, please maintain with the factory, and carry out under the guidance of professionals. Otherwise, unforeseen problems may occur during the experiment.

1

  3. Design of constant calculation

  3.1 Constant settings

  Constants are used in the design of calculation quantities and can be set to a fixed value or a preset sequence of numbers. In a template, up to 64 constants can be designed. Select a location in the list on the left, fill in the name and set value of the constant in the column on the right, and click Save.

  If you want to delete a constant, select the constant you want to delete in the list on the left and click the delete button.

  There are two types of constants, one is a fixed value, and the other is a series. If you want to design a series constant, when designing a constant, click the button behind the numerical input field and edit the series in the pop-up dialog box.

  Sequence constants. During the experiment, every time a new row of data is added, constants will pop up one by one in order from top to bottom for use in calculation formulas. After the last value of the number column is popped up, if the number of data rows is still increasing, the last value will be popped up repeatedly.

1

1

  3.2 Calculation amount setting

  The calculated amount refers to the value obtained by editing the calculation formula based on the data and constants collected by the sensor. In the process of data collection, these calculations will be generated synchronously with the sensor reading data.

  Select a space in the list on the left to set a calculation amount. A template supports up to 64 calculations. The related attributes of the calculation amount are described as follows:

  name. The name of the calculated amount displayed in the graph, table, etc.

  The number of decimal places. The maximum number of decimal places for this calculation.

  Minimum value. The smallest possible amount of calculation.

  Maximum value. The maximum possible amount of calculation. Trigger amount. (Not used temporarily)

  Number of trigger lines. (Not used temporarily) Calibration value. After the value is calculated, a numerical value is added.

  company name. The unit of the calculation amount displayed in a graph, etc.

  expression. The expression used to calculate the calculated amount. Please use formula button and data volume button to obtain

  Calculate the available formulas and data sources (sensor quantities, constants, other calculation quantities). If the input formula is correct, the corresponding description of the formula will be displayed in the bottom line. You can also click the check button after the expression to check whether the input formula is correct Meet the grammatical requirements

  After editing, click the save button to save the calculated amount, if you want to delete the calculated amount, click the delete button.

11

  4. Constant input window

  Select Tools->Constant Calculation Quantity Design->Constant Input Window to instantly adjust the constants during the current sampling process. First select the constant targeted by the constant input window. If the constant is a fixed value constant, the fixed value will be displayed in the input box and can be changed at any time. The changed value is only valid when you click the accept button on the right side of the input box. If it is a series of constants, the series will be displayed in the list and the next value to be used will be highlighted. Modify the value in the input box and click the Accept button, then the next value will be changed accordingly. Note that the constant is only valid for the current sample after being modified here. When the next sample is taken, the value will still be restored to the fixed value or number sequence set by the template. The fixed value or number sequence of the template must be modified in Tools -> Constant Calculation Design.

1

  5. Experimental data management

  The collected experimental data can be managed through this function. On the interface, you can select the sampling data once, and then delete the sampling data for that time, or you can choose to copy the frame and data. If it is a copy frame, the system will generate a new sampling frequency. The structure of this data is the same as that of the copied one, but it does not contain data. Copying data completely copies the frame and data of the specified sampling times.

1

  Five, data display method

  1. Sensor

  Sensor status display

  In the online state, after opening the sensor window, several sensor display windows will pop up according to the actual number of connected sensors. The user can switch the display mode: graph, instrument or digital mode.

  在脱机状态下,用户可以通过“新增”菜单向模板手工添加传感器,并通过点击“删除”菜单去掉多余的传感器。在传感器窗口上,点击传感器的名称可以弹出传感器选择窗口,在此可以指定传感器的类型。

1

 

  2、图形

1

  2.1 菜单栏

  复制图形。 点击后将当前图形保存至剪贴板,可以粘贴到任何支持图形的编辑器中, 包 括本系统提供的报告制作窗口。

  标签管理。 可以增加、删除当前窗口图形中的文字标签。

  清除分析线。 点击后全部删除当前窗口图形中的拟合、统计、面积等分析线。

  2.2 顶部工具栏

  图形标题输入框。 修改当前窗口图形的顶部标题文字。

  曲线标题。 点击后切换显示/不显示当前窗口图形中的曲线图例。

  采样次数。 点击后选择显示在当前窗口图形中的实验数据的采样次数。

  选择方式。 设置在当前窗口图形中用鼠标选择的方式。

  选择区域。 用鼠标拉框选择要放大显示的区域。

  选择数据。 用鼠标拉框选择要分析的数据。

  选择标签。 用鼠标点选要拖动的文字标签。

  取消选择。 鼠标不选择然后内容。

  2.3 左侧工具栏

  显示。 点击切换显示/不显示左侧Y轴及数据曲线。

  标题。 设置在左侧Y轴上的标题。

  坐标。 设置左侧Y轴的坐标数值范围,点击自动缩放,则该轴会根据实际显示数据 的大小自动调整坐标范围至最合理。

  曲线。 选择该轴上显示的数据列。被选中的数据可设定是否显示线条和是否显示 数据点。

  2.4 右侧工具栏

  显示。点击切换显示/不显示右侧Y轴及数据曲线。

  标题。设置在右侧Y轴上的标题。

  坐标。设置右侧Y轴的坐标数值范围,点击自动缩放,则该轴会根据实际显示数据 的大小自动调整坐标范围至最合理。

  曲线。选择该轴上显示的数据列。被选中的数据可设定是否显示线条和是否显示数 据点。

  2.5 底部工具栏

  标题。设置在X轴上的标题。

  坐标。设置X轴的坐标数值范围,点击自动缩放,则该轴会根据实际显示数据的大 小自动调整坐标范围至最合理。

  数据。选择该轴上的数据列。

  All zoom automatically. After clicking, the X axis, the left Y axis, and the right Y axis of the graph in the current window will all enter the automatic coordinate adjustment state.

  2.6 Central chart area operation

  When the mouse is hovering over a point on the data curve, the name and value of the point will be displayed on the mouse prompt.

  Select the area status. After dragging with the left button of the mouse, the selection area appears, and after releasing the mouse, a dialog box for selecting the magnification mode appears. The selectable magnification methods include:

  The Y axis is zoomed in separately.

  The X axis is zoomed in separately.

  The X axis and Y axis are simultaneously zoomed in.

  The X axis and Y axis are not zoomed in.

  Y2 axis zoom. (Y2 axis refers to the right Y axis, and Y axis refers to the left Y axis.)

  Select the data status. After dragging with the left button of the mouse, the selection area will appear. After releasing the mouse, the selection dialog box for data operation will pop up.

  Data excluded. It means to exclude the data points in the selected area from the current graph. After selecting this operation, the curve selection dialog box will pop up, and the selected curve will be excluded. Note that this operation only excludes data points in the current graph, and these data still exist in the sampled data. If you load a new graphic or refresh this graphic, then

  data analysis. It means that the data points in the selected area in the current graph participate in analysis and calculation.

  ua After selecting this operation, the curve selection dialog box will pop up, and the selected curve will be excluded.

  After ub selects the curve, the analysis method selection dialog box pops up, and you can set whether to draw an extension line to the fitted curve, and whether to display the text label of the fitting formula or the statistical result on the graph.

  Do nothing. It means that if the current selection is a misoperation, then exit without any processing.

111

  3. Form

  The system displays all the data columns by default. Part of the data column can also be blocked by setting. Through the sampling times menu item, you can set which sampling data is currently displayed.

  The size of numeric characters displayed in the table can be adjusted by zooming in, zooming out and restoring.

1

  4. Instrument

  After opening the meter window, you need to first set which data column the meter displays. The selectable range includes sensor data and calculated data. The system will automatically set the scale range and the number of scales of the meter, or it can be adjusted manually.

1

  5. Thermometer

  After opening the thermometer window, you need to first set which data column the thermometer displays. The optional range includes sensor data and calculated data. The system will automatically set the scale range of the thermometer, or it can be adjusted manually. At the same time, you can also set whether to display the right scale. The system defaults that the left scale is Celsius and the right is Fahrenheit. The system will automatically synchronize the scales on both sides.

1

  6. Numbers

  After opening the digital window, you need to first set which data column the digital window displays. The optional range includes sensor data and calculated data. The value displayed in this window will automatically adjust the height of the character to the best display effect according to the length of the number.

1

We could not find any corresponding parameters, please add them to the properties table